Skip to content

Rover Installer Command-Line Options ​

This document describes the command-line properties available when installing Rover using msiexec.

Overview ​

The Rover installer supports silent and automated installations through MSI command-line properties. These properties allow administrators to pre-configure the application without user interaction.

Basic Usage ​

cmd
msiexec /i "rover-installer.msi" /qn [PROPERTIES...]
FlagDescription
/iInstall the specified MSI package
/qnQuiet mode, no UI
/qbBasic UI (progress bar only)
/l*v install.logEnable verbose logging to file

Configuration Properties ​

Core Settings ​

PropertyValuesDescription
CLI_RESET_CONFIG"1" or "0"When "1", overwrites existing configuration file during upgrade. Default behavior preserves existing configuration.
CLI_SHOWMULTIPLE"1" or "0"When "1", enables the configuration file selector dropdown on the login form, allowing users to switch between multiple configuration files.
CLI_PROMPTMODE"1", "2", or "3"Controls visibility and editability of advanced fields. See Prompt Modes below.

Connection Settings ​

PropertyExample ValueDescription
CLI_SERVER_ADDRESS"myserver.example.com"Default server address/hostname for connection
CLI_SERVER_PORT"22"Default port number (typically 22 for SSH, 23 for Telnet)
CLI_CONNECTION_TYPE"SSH" or "TELNET"Connection protocol to use
CLI_ACCOUNT"MYACCOUNT"Default account name

Field Visibility Overrides ​

These properties override the CLI_PROMPTMODE setting for individual fields. Set to "1" to show, "0" to hide.

PropertyDescription
CLI_SHOW_ADDRESSShow/hide the Server Address field
CLI_SHOW_PORTShow/hide the Port field
CLI_SHOW_CONNECTION_TYPEShow/hide the Connection Type dropdown
CLI_SHOW_ACCOUNTShow/hide the Account field

Field Read-Only Overrides ​

These properties override the CLI_PROMPTMODE setting for individual fields. Set to "1" for read-only, "0" for editable.

PropertyDescription
CLI_READONLY_ADDRESSMake Server Address read-only or editable
CLI_READONLY_PORTMake Port read-only or editable
CLI_READONLY_CONNECTION_TYPEMake Connection Type read-only or editable
CLI_READONLY_ACCOUNTMake Account read-only or editable

Note: Username and Password fields are always shown on the main form and are always editable. They cannot be made read-only or hidden.

Prompt Modes ​

The CLI_PROMPTMODE property provides a simplified way to configure field visibility and editability:

ValueNameBehavior
"1"Show All PromptsAll fields (Server, Port, Connection Type, Account) are visible on the main login form and fully editable.
"2"Hide EditableAdvanced fields are hidden from the main form but appear in a collapsible "Additional Settings" section. Fields remain editable.
"3"Hide Read-OnlyAdvanced fields are hidden from the main form and appear in a collapsible "Additional Settings" section. Fields are read-only (users cannot modify pre-configured values).

Login Form Layout ​

PROMPTMODE=1 (Show All):

┌─────────────────────────────┐
│ Server:      [____________] │
│ Port:        [____________] │
│ Connection:  [SSH      ▼ ] │
│ Username:    [____________] │
│ Password:    [____________] │
│ Account:     [____________] │
│                             │
│   [Sign On]    [Exit]       │
└─────────────────────────────┘

PROMPTMODE=2 or 3 (Hidden fields):

┌─────────────────────────────┐
│ Username:    [____________] │
│ Password:    [____________] │
│                             │
│   [Sign On]    [Exit]       │
│                             │
│ ▶ Additional Settings       │
│ ┌─────────────────────────┐ │
│ │ Server:    [__________] │ │
│ │ Port:      [__________] │ │
│ │ Connection:[SSH     ▼ ] │ │
│ │ Account:   [__________] │ │
│ └─────────────────────────┘ │
└─────────────────────────────┘

Installation Examples ​

Example 1: Basic Silent Install with Server Configuration ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_SERVER_ADDRESS="production.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="PROD"

Example 2: Locked-Down Installation (Users Can Only Enter Credentials) ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_PROMPTMODE="3" ^
    CLI_SERVER_ADDRESS="secure.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="LOCKED"

Example 3: Flexible Installation (Hidden but Editable Settings) ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_PROMPTMODE="2" ^
    CLI_SERVER_ADDRESS="default.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="DEFAULT"

Example 4: Upgrade with Configuration Reset ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_RESET_CONFIG="1" ^
    CLI_SERVER_ADDRESS="newserver.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="NEWACCT"

Example 5: Enable Multiple Configuration Files ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_SHOWMULTIPLE="1" ^
    CLI_PROMPTMODE="1" ^
    CLI_SERVER_ADDRESS="server1.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="ACCT1"

Example 6: Custom Field Visibility (Override PROMPTMODE) ​

Show all fields except Account, make Port read-only:

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_PROMPTMODE="1" ^
    CLI_SHOW_ACCOUNT="0" ^
    CLI_READONLY_PORT="1" ^
    CLI_SERVER_ADDRESS="server.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="HIDDEN"

Example 7: Silent Install with Logging ​

cmd
msiexec /i "rover-installer.msi" /qn /l*v "C:\Logs\rover_install.log" ^
    CLI_SERVER_ADDRESS="server.example.com" ^
    CLI_SERVER_PORT="22" ^
    CLI_CONNECTION_TYPE="SSH" ^
    CLI_ACCOUNT="MYACCT"

Upgrade Behavior ​

By default, the installer preserves existing configuration files during upgrades:

ScenarioCLI_RESET_CONFIGResult
Fresh installN/ANew configuration created from template with specified values
Upgrade, config exists"0" or not setExisting configuration preserved (CLI values ignored)
Upgrade, config exists"1"Existing configuration overwritten with new values

Configuration Files ​

The installer writes to two configuration files:

  1. configuration.json - Located in %APPDATA%\Zumasys\Rover\

    • Contains connection settings, field visibility, and read-only states
  2. settings.json - Located in %APPDATA%\Zumasys\Rover\

    • Contains the AllowMultipleConfigs setting

Troubleshooting ​

Verify Installation Properties ​

Enable verbose logging to verify properties are being passed correctly:

cmd
msiexec /i "rover-installer.msi" /l*v "install.log" CLI_SERVER_ADDRESS="test"

Then search install.log for CustomActionData to see the values received by the installer.

Common Issues ​

IssueCauseSolution
Settings not appliedExisting config preservedUse CLI_RESET_CONFIG="1"
Fields still editableWrong PROMPTMODEUse CLI_PROMPTMODE="3" for read-only
Fields not hiddenIndividual overrideCheck for conflicting CLI_SHOW_* properties

Property Reference Summary ​

cmd
msiexec /i "rover-installer.msi" /qn ^
    CLI_RESET_CONFIG="0|1" ^
    CLI_SHOWMULTIPLE="0|1" ^
    CLI_PROMPTMODE="1|2|3" ^
    CLI_SERVER_ADDRESS="hostname" ^
    CLI_SERVER_PORT="port" ^
    CLI_CONNECTION_TYPE="SSH|TELNET" ^
    CLI_ACCOUNT="account" ^
    CLI_SHOW_ADDRESS="0|1" ^
    CLI_SHOW_PORT="0|1" ^
    CLI_SHOW_CONNECTION_TYPE="0|1" ^
    CLI_SHOW_ACCOUNT="0|1" ^
    CLI_READONLY_ADDRESS="0|1" ^
    CLI_READONLY_PORT="0|1" ^
    CLI_READONLY_CONNECTION_TYPE="0|1" ^
    CLI_READONLY_ACCOUNT="0|1"